<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-25 11-39-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 54 dBuV Classic
Pilot RDS Phase Difference
6.7 kHz 2.9 kHz 85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 19057 0,0052
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,4 dBr 1,89 dBr 3,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Solistes De L'orchestre National De France "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 0,0052 Acquired: 2025/06/25 11.38.07 Total samples: 19057 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,8 dBr MIN: 0,4 dBr AVE: 1,89 dBr % above 12,2 dBr: 0,0 Last value: 0,8 dBr (2025/06/25 11.38.06) 11.24 11.26 11.28 11.30 11.32 11.34 11.36 11.38 -1 0 1 2 3 4 Pm [dBr]